永旺彩票Electrophoresis equipment maintenance and maintenance methods, electrophoresis equipment (electrophoresis tank, spray tank, electrophoresis power supply, electrophoresis recycling ultrafiltration machine, electrophoresis coating equipment) electrophoresis paint (color electrophoresis paint, cathodic electrophoresis paint, anodic electrophoresis paint) products are dumb Light, flat light, highlight and color
(1) Circulation volume: 4 times of tank liquid volume/hr. Insufficient circulation may result in deposits on the bottom of the tank and on the surface of the workpiece.
(2) Surface speed: Low surface speed may cause deposition on the surface of the workpiece.
永旺彩票(3) The liquid level of the main and auxiliary tanks drops.
永旺彩票(4) There is no spray at the bottom of the storage tank: the fall of the glass fiber reinforced plastic lining in the storage tank may cause repeated deposition and dissolution of the paint, corrosion of the tank wall and a threat to personal safety.
永旺彩票(5) Appropriate filtration accuracy: Good filtration is an important measure for the coating film to be free of particles.
(6) Good temperature control heat exchange system: heat exchange for circulation and electrophoresis, it is very important to control the bath temperature. The electrophoresis tank needs constant temperature during the production process, so the circulation tank must have a heat exchange system and sufficient heat exchange capacity. The temperature of the heat exchange medium is required: cooling: 5-15℃, heating: <50℃. Recommended bath temperature control during long-term shutdown: 20~25℃
Into shengjichuan+
Product Center+